ABSTRACT : |
This study involves performance analysis of Conventional LPG Cooking Stove. A Conventional LPG burner is taken to carry out a series of experiments. Thermal efficiency of LPG burner is measured for a wide range of parameters such as loading height, pot diameter, and loading weight. The maximum thermal efficiency of 61.66% could be achieved with the present burner. Emission levels for species namely CO, CO2, and NOX are measured at different power levels. The maximum NOX emission level for this burner is around 49 ppm. The experimental method was carried out using water boiling test and emission test according to IS 4246:2002 involving different parameters.
Keywords: LPG, Conventional LPG stove, burner, efficiency, emission |
|